From: Mapping the low enthalpy geothermal potential of shallow Quaternary aquifers in Finland
Climatic zone I | Climatic zone II | |||||||
(minimum outside temperature = -26C) | (minimum outside temperature = -29C) | |||||||
Class | Detached house | Apartment building | Detached house | Apartment building | ||||
 | Design power (W/m 2 ) | Design power (W/m 2 ) | Design power (W/m 2 ) | Design power (W/m 2 ) | ||||
 | Heating | Re-heating of air supply unit | Heating | Re-heating of air supply unit | Heating | Re-heating of air supply unit | Heating | Re-heating of air supply unit |
A | 97 | - | 65 | - | 103 | - | 69 | - |
B | 34 | 9 | 16 | 12 | 36 | 10 | 17 | 13 |
C | 25 | 7 | 12 | 10 | 26 | 8 | 13 | 11 |
Climatic zone III | Climatic zone IV | |||||||
(minimum outside temperature = -32C) | (minimum outside temperature = -38C) | |||||||
Class | Detached house | Apartment building | Detached house | Apartment building | ||||
 | Design power (W/m 2 ) | Design power (W/m 2 ) | Design power (W/m 2 ) | Design power (W/m 2 ) | ||||
 | Heating | Re-heating of air supply unit | Heating | Re-heating of air supply unit | Heating | Re-heating of air supply unit | Heating | Re-heating of air supply unit |
A | 109 | - | 74 | - | 121 | - | 82 | - |
B | 38 | 11 | 18 | 15 | 42 | 14 | 20 | 17 |
C | 28 | 10 | 14 | 12 | 31 | 12 | 15 | 15 |