Skip to main content

Science – Society – Technology

Table 2 Summary of the experimental conditions and results

From: Experimental study on convective heat transfer of an open-loop borehole heat exchanger

Diameter (mm)

Flow mode

Flow rate (m3/h)

Re

Outlet temperature θo

17

Forward

0.3

2092

0.13

17

Forward

0.4

2789

0.05

17

Forward

0.45

3138

0.02

20

Forward

0.3

1975

0.07

20

Forward

0.4

2633

0.09

20

Forward

0.45

2962

0.13

23

Forward

0.3

1870

0.13

23

Forward

0.4

2493

0.24

23

Forward

0.45

2805

0.28

17

Backward

0.4

2789

0.52

20

Backward

0.4

2633

0.53

23

Backward

0.4

2493

0.59