Science – Society – Technology
Parameter | Value | Units |
---|---|---|
Fuild properties | ||
Thermal conductivity | 0.468 | \(\text {W}\,\text {m}^{-1}\,\text {K}^{-1}\) |
Density | 1026 | \(\text {kg}\,\text {m}^{-3}\) |
Volumentric heat capacity | 4123,494 | \(\text {J}\,\text {m}^{-3}\,\text {K}^{-1}\) |
Dynamic viscosity | 0.00337 | Pa s |
BHE geometry | ||
Length | 120 | m |
Diameter | 0.150 | m |
Shank space | 0.083 | m |
Outer diameter pipes | 0.0334 | m |
Pipe wall thickness | 0.0037 | m |
BHE-properties | ||
Thermal conductivity grout | 2.0 | \(\text {W}\,\text {m}^{-1}\,\text {K}^{-1}\) |
Volumetric heat capacity grout | 3900000 | \(\text {J}\,\text {m}^{-3}\,\text {K}^{-1}\) |
Thermal conductivity pipe | 0.4 | \(\text {W}\,\text {m}^{-1}\,\text {K}^{-1}\) |
Ground properties | ||
Average thermal conductivity | 1.9 | \(\text {W}\,\text {m}^{-1}\,\text {K}^{-1}\) |
Average volumetric heat capacity | 2052000 | \(\text {J}\,\text {m}^{-3}\,\text {K}^{-1}\) |
Undisturbed ground temperature | 15.0 | \(^\circ {C}\) |