Skip to main content

Science – Society – Technology

Table 4 Properties of system’s different points

From: Exergy and exergoenvironmental assessment of a geothermal heat pump and a wind power turbine hybrid system in Shanghai, China

State

Working fluid

Mass flow rate (kg/s)

Pressure (kPa)

Temperature (°C)

Enthalpy (kJ/kg)

Entropy (kJ/kg)

1

R134a

0.5101

200

−5.093

248.7

0.9538

2

R134a

0.5343

1200

66.99

297.3

0.9843

3

R134a

0.5343

1200

41.29

110.2

0.4004

4

R134a

0.5101

200

−10.09

102.7

0.399

5

water

4.782

250

35

146.8

0.5049

6

water

4.782

250

30

125.9

0.4365

7

Geo-fluid

4.432

250

7

28.47

8

Geo-fluid

4.432

250

11

45.27

9

R134a

0.02421

400

21.1

266.9

0.9662

10

R134a

0.5101

1200

36.29

102.7

0.3766

11

R134a

0.5101

400

21.1

266.9

0.9662

12

R134a

0.5343

400

21.1

266.9

0.9662

13

R134a

0.02421

400

8.91

110.2

0.4115