Science – Society – Technology
State | Unit | Component | Data design | Data model | Error (%) |
---|---|---|---|---|---|
Rated capacity | kW | Turbine | 60000 | 60218 | 0.36 |
Steam flowrate | kg/h | 411729 | 411228 | − 0.12 | |
Inlet cooling water mass flow rate | kg/h | Inter-condenser | 565999 | 565236 | − 0.13 |
Outlet condensate mass flow rate | kg/h | 578483 | 575460 | − 0.52 | |
Inlet cooling water mass flow rate | kg/h | After-condenser | – | 672120 | – |
Outlet condensate mass flow rate | kg/h | – | 684360 | – | |
Inlet cooling water mass flow rate | kg/h | Condenser | 7,381,203 | 7387200 | 0.08 |
Outlet condensate mass flow rate | kg/h | 8384034 | 8359200 | − 0.30 | |
Enthalpy | kJ/kg | - | 2221 | – | |
Inlet cooling water mass flow rate | kg/h | Cooling tower | 8194420 | 8247600 | 0.65 |
Suction steam rate | kg/h | Ejector 1st | 9531 | 9648 | 1.23 |
Suction steam rate | kg/h | Ejector 2nd | – | 12240 | – |
MCWP power | kW | MCWP | 60000 | 60218 | 0.36 |