Skip to main content

Science – Society – Technology

Table 4 Optimization results using genetic algorithm and Nelder–Mead simplex method

From: Exergy analyses and optimization of a single flash geothermal power plant combined with a trans-critical CO2 cycle using genetic algorithm and Nelder–Mead simplex method

Parameters

Definition

Initial mode

Optimal mode using genetic algorithm

Optimal mode using Nelder–Mead simplex method

Units

\(P_{2}\)

Separator pressure

500

304.3

326.4

kPa

\(P_{10}\)

CO2 turbine inlet pressure

15,000

13,083

12,067

kPa

\(P_{5}\)

Steam turbine exit pressure

20

37.36

22.01

kPa

Wtur, steam

The power output of the steam turbine

150.1

194.2

218.1

kW

\(W_{{{\text{tur}},{\text{ CO}}_{2} }}\)

The power output of the CO2 turbine

525.5

606.8

460.8

kW

Wpump, steam

Power consumption of pump 1

0.2436

0.2626

0.2762

kW

\(W_{{{\text{pump}},\;{\text{CO}}_{2} }}\)

Power consumption of pump 2

274.1

235.6

219

kW

Wnet

Total net power output

401.3

316

459.5

kW

\(\eta_{{{\text{ex}}}}\)

Exergy efficiency

32.46

39.21

36.16

%