Table 4 Mean Darcy flux [m d−1] for the whole fault area for the four given hydraulic conductivities

From: Finite element simulation of permeable fault influence on a medium deep borehole thermal energy storage system

Thickness

Darcy flux

[m d−1]

 

[m]

[10–3 m s−1]

[10–4 m s−1]

[10–5 m s−1]

0.5

1.26

0.146

0.0194

1

1.23

0.140

0.0193

2

1.19

0.135

0.0190

3

1.16

0.132

0.0187

4

1.14

0.131

0.0185