Skip to main content

Science – Society – Technology

Table 4 Temperature difference comparison for different numerical setups

From: Modeling neighborhood-scale shallow geothermal energy utilization: a case study in Berlin

 

Max. 1 day time stepping \(\Delta T_{abs} [K] (\Delta T_{rel} [\%])\)

Max. 5 days time stepping \(\Delta T_{abs} [K] (\Delta T_{rel} [\%])\)

Max. 15 days time stepping \(\Delta T_{abs} [K] (\Delta T_{rel} [\%])\)

FEFLOW (using \(T_{\text {out}}^{n-1}\))

0.940 (1.05)

0.883 (7.05)

0.880 (7.37)

OGS model 1 (using \(T_{\text {out}}^{n}\))

0.943 (0.74)

0.929 (2.21)

0.927 (2.42)

OGS model 2 (using \(T_{\text {out}}^{n-1}\))

0.944 (0.63)

0.943 (0.74)

0.887 (6.63)