Science – Society – Technology
From: Economic and fault stability analysis of geothermal field development in direct-use hydrothermal reservoirs
Parameter
Value
Unit
\(\sigma _{1}\)
45
MPa
\(\sigma _{2}\)
34
\(\sigma _{3}\)
30
Young’s modulus
16
GPa
Poisson’s ratio
0.25
–
Cohesion coefficient
0
Inital pore pressure
20.1