Skip to main content

Science – Society – Technology

Table 3 Input data for the fault model

From: Economic and fault stability analysis of geothermal field development in direct-use hydrothermal reservoirs

Parameter Value Unit
\(\sigma _{1}\) 45 MPa
\(\sigma _{2}\) 34 MPa
\(\sigma _{3}\) 30 MPa
Young’s modulus 16 GPa
Poisson’s ratio 0.25
Cohesion coefficient 0 MPa
Inital pore pressure 20.1 MPa
  1. The stress tensor values are based on the work of Mechelse (2017)