Table 1 Input data for the reservoir model

From: Economic and fault stability analysis of geothermal field development in direct-use hydrothermal reservoirs

Parameter Value Unit
nx × ny × nz 60 × 40 × 42
dx × dy × dz 30 × 30 × 2.5 m
Permeability range 1–3400 mD
Porosity range 5–30 %
Location producer 450,600 m (X,Y)
Location injector 1440,600 m (X,Y)
Fault permeability See Table 2 mD
Fault thickness 30 m
Overburden permeability \(9.9 \times 10^{-15}\) (0.001) \(\hbox {m}^{2}\) (mD)
Top reservoir depth 2200 m
Model reservoir thickness 105 m
Fault-wells distance see Table 2 m
Uniform initial pressure 20.1 MPa
Uniform initial temperature 345.75 K
Flowrate prod/inj 4200 \(\hbox {m}^{3}/\hbox {day}\)
Injection temperature see Table 2 K
Simulation time 30 \(\times\) 365 days
Thermal conductivity rock 100 kJ/m/day/K
Heat capacity rock 2200 \(\hbox {kJ/m}^{3}/\hbox {K}\)