Fig. 2From: Monitoring of a reverse cement job in a high-temperature geothermal environmentTemperature (blue line) and pressure (black line) logged on September 6th at 15:00, Q = 0 l/s. Temperature (red line) logged on September 7th at 14:04 after completion of cementing job. Cement bond logs were carried out subsequently. Depth reference is Thor rig floor (9.0 m above surface). Figure modified from (Stefánsson et al. 2020)Back to article page