Skip to main content

Science – Society – Technology

Table 9 Key results comparing insulating properties for only Casg1 and for all casings to 3.s.f

From: Modelling an unconventional closed-loop deep borehole heat exchanger (DBHE): sensitivity analysis on the Newberry volcanic setting

Key results Only Casg1 All casings
\({T}_{\text{i}}\; (^{\circ } {\text{C}})\) 11.1 10.9
\({{T}}_{\text{o}}\; (^{\circ } {\text{C}})\) 50.0 17.8
\({\Delta } {T} \;(^{\circ }{\text{C}})\) 38.9 6.92
\({{P}}_{\text{i}}\) (MPa) 4.97 5.23
\({{P}}_{\text{o}}\) (MPa) 0.302 0.302
\({q}_{\text{Th}}\) (MW) 1.46 0.785