Science – Society – Technology
From: Laboratory tests simulating corrosion in geothermal power plants: influence of service conditions
Phase | Rs (Ω·cm2) | Error (%) | Cfilm (F) | Error (%) | nfilm | Error (%) | Rfilm (Ω·cm2) | Error (%) | Cdl (F) | Error (%) | ndl | Error (%) | Rct (Ω·cm2) | Error (%) | χ2 |
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
1 | 38 | 1.0 | 4.2E−08 | 30.5 | 0.74 | 6.8 | 30 | 17.9 | 1.1E−06 | 13.5 | 0.76 | 2.6 | 20,482 | 10.4 | 7.4E−05 |
2 | 76 | 1.0 | 1.5E−08 | 8.3 | 0.64 | 2.8 | 75 | 3.0 | 2.7E−06 | 1.2 | 0.76 | 1.2 | 473 | 2.0 | 6.9E−05 |
3 | 41 | 0.5 | 6.3E−08 | 7.2 | 0.59 | 2.3 | 37 | 4.3 | 2.9E−06 | 2.9 | 0.79 | 1.1 | 11,506 | 21.1 | 2.1E−05 |
4 | 41 | 0.5 | 6.3E−08 | 8.5 | 0.61 | 2.5 | 36 | 5.1 | 2.8E−06 | 3.5 | 0.79 | 1.2 | 15,169 | 25.4 | 2.6E−05 |
5 | 40 | 0.6 | 6.9E−08 | 10.2 | 0.60 | 3.1 | 39 | 6.9 | 3.2E−06 | 4.8 | 0.76 | 1.6 | 12,331 | 26.1 | 3.0E−05 |