Skip to main content

Science – Society – Technology

Table 4 Summary analysis of production casing and tieback casing load calculation for wells HCE9B and HCE28B

From: Casing failure identification of long-abandoned geothermal wells in Field Dieng, Indonesia

Well

Production casing data

Burst (MPa)

Collapse (MPa)

Tension (kN)

Casing grade/pounder

Casing depth (m TVD/MD)

Resultant (design factor)

Burst ratinga

Evaluation

Resultant (design factor)

Collapse ratinga

Evaluation

Resultant (design factor)

Tension ratinga

Evaluation

HCE9B

339.7 mm K-55

101.2 kg/m

Top

0

38.7

23.8

Failed

0

13.4

Accepted

3073

4755

Accepted

Bottom

1519/1613

23.8

18.1

Failed

45

10.2

Failed

0

3614

Accepted

HCE28B

339.7 mm K-55

101.2 kg/m

Top

0

40

23.8

Failed

0

13.4

Accepted

2930

4755

Accepted

Bottom

1504/1538

25.7

16.7

Failed

40

9.4

Failed

0

3337

Accepted

Tieback 273.1 mm L-80

82.3 kg/m

Top

0

40

44.5

Accepted

0

27.7

Accepted

2391

5676

Accepted

Bottom

1504/1538

25.7

31.2

Accepted

40

19.5

Failed

0

3983

Accepted

  1. aBurst, collapse, and tension rating were corrected based on temperature