Skip to main content

Science – Society – Technology

Geothermal Energy Cover Image

Table 3 Median values of \({\text{SC}}_{{x_{{i,{ \text{min} }}} - x_{i,s} ,F_{j} }}\) for the evenly/log-evenly spaced parameters

From: Hydraulic behavior of fault zones in pump tests of geothermal wells: a parametric analysis using numerical simulations for the Upper Jurassic aquifer of the North Alpine Foreland Basin

Variable value normalized on parameter range [%] Water viscosity Matrix permeability Fault zone storage Fault zone permeability Matrix storage
20 0.017 0.058 0.149 0.441 2.819
40 0.058 0.620 0.270 2.189 3.522
60 0.113 3.297 0.444 6.914 3.590
80 0.177 7.870 0.570 8.968 2.578
100 0.245 9.893 0.691 8.972 3.759