Table 6 Taguchi response table for heat transfer rate in EATHE system

From: Optimization of operating parameters of earth air tunnel heat exchanger for space cooling: Taguchi method approach

Level Factor A Factor B Factor C Factor D
1 51.30 55.50 54.90 52.99
2 56.78 57.03 57.37 56.50
3 59.86 58.47 58.36 59.53
4 62.30 59.24 59.60 61.20
Delta 11.00 3.74 4.70 8.21