Skip to main content

Science – Society – Technology

Table 3 Geothermometer calculations for KA-1 (all values in °C)

From: Effect of an 860-m thick, cold, freshwater aquifer on geothermal potential along the axis of the eastern Snake River Plain, Idaho

Sample

Chalcedonya

Quartza

Na/Kb

Na/Kc

Na–K–Cad

Na–K–Ca–Mge

Kb/Mgc

KA-1

141

164

143

163

139

125

80.2

  1. aFournier (1977)
  2. bFournier (1979)
  3. cGiggenbach (1988)
  4. dFournier and Truesdell (1973)
  5. eFournier and Potter (1979)