Table 1 Thermal performance with varying the Hurst coefficient

From: The effect of spatial aperture variations on the thermal performance of discretely fractured geothermal reservoirs

\(\zeta\) \(\bar{\Theta }_p\) \(\sigma _{\Theta }\) F
0.1 0.786 ± 0.002 0.063 ± 0.001 0.41 ± 0.01
0.2 0.785 ± 0.002 0.065 ± 0.001 0.40 ± 0.01
0.3 0.784 ± 0.002 0.067 ± 0.001 0.40 ± 0.01
0.4 0.784 ± 0.002 0.069 ± 0.001 0.40 ± 0.01
0.5 0.784 ± 0.002 0.069 ± 0.001 0.39 ± 0.01
0.6 0.784 ± 0.002 0.071 ± 0.001 0.40 ± 0.01
0.7 0.783 ± 0.002 0.072 ± 0.001 0.39 ± 0.01
0.8 0.783 ± 0.002 0.072 ± 0.001 0.39 ± 0.01
0.9 0.784 ± 0.002 0.073 ± 0.001 0.40 ± 0.01
1 0.784 ± 0.002 0.073 ± 0.001 0.40 ± 0.01
  1. The statistical values are reported with a 95 % confidence interval determined using resampling based on the bootstrapping method