Skip to main content

Science – Society – Technology

Geothermal Energy Cover Image

Table 2 Performance of VCC with different T c

From: Performance analysis and working fluid selection for geothermal energy-powered organic Rankine-vapor compression air conditioning

Fluid type Tc(°C) COPc PR CRPR N(kg/t)
R123 35 6.41 3.20 2.00 1,366.7
R123 40 5.36 3.78 1.42 893.32
R123 45 4.56 4.45 1.02 575.81
R134a 35 5.30 2.54 2.09 1,475.9
R134a 40 4.46 2.91 1.53 1,005.8
R134a 45 3.58 3.32 1.08 618.99
R245fa 35 6.10 3.20 1.91 1,364.8
R245fa 40 5.05 3.78 1.34 887.59
R245fa 45 4.27 4.45 0.96 568.8
R600a 35 5.77 2.49 2.32 1,402.9
R600a 40 4.76 2.85 1.67 911.84
R600a 45 3.99 3.24 1.23 583.79
R600 35 6.03 2.64 2.28 1,385.8
R600 40 5.00 3.05 1.64 902.63
R600 45 4.22 3.49 1.21 579.49
R290 35 3.41 3.00 1.14 1,020.2
R290 40 2.87 3.37 0.85 689.69
R290 45 2.43 3.78 0.64 455.06