Skip to main content

Science – Society – Technology

Table 1 Thermal conductivities λ of bucket samples from the drilling at the study site in Biberach an der Riß

From: Evaluating an enhanced thermal response test (ETRT) with high groundwater flow

Sampling depth

Thermal conductivity

z [m bgl]

λ [W m−1 K−1]

0.54–1.57

1.9 ± 0.2

1.57–2.74

1.5 ± 0.1

2.74–3.00

2.2 ± 0.1

3.00–3.40

2.4 ± 0.1

3.40–4.61

2.5 ± 0.1

4.61–5.33

2.1 ± 0.1

4.61–5.33

2.7 ± 0.1

5.33–6.62

2.7 ± 0.1

6.62–7.56

2.5 ± 0.1

7.56–8.00

2.3 ± 0.1

8.00–8.60

2.6 ± 0.1

8.60–9.64

2.9 ± 0.1

9.64–10.91

2.5 ± 0.1

11.00–11.48

2.8 ± 0.1

11.48–13.00

2.7 ± 0.1

13.00–13.75

2.8 ± 0.1

13.75–15.00

2.8 ± 0.1

15.00–15.41

2.6 ± 0.1

15.41–15.78

2.3 ± 0.1

15.78–17.63

2.7 ± 0.1

17.63–19.00

2.4 ± 0.1

19.00–19.43

2.5 ± 0.1

19.43–19.64

2.5 ± 0.1

19.64–21.00

2.6 ± 0.1

21.00–23.43

2.6 ± 0.1

Average

2.5 ± 0.4